rc 76 (10) during FALL BACK job AXFFB01
search cancel

rc 76 (10) during FALL BACK job AXFFB01

book

Article ID: 126174

calendar_today

Updated On:

Products

Datacom DATACOM - AD

Issue/Introduction

AAC03 T311JDPE CLOSE15 00 542 00.08 00.33 00
CA11MUF:DB00135I - CONNECT TO CA11MUF CA11MF1 JOB81570 SYP R12 SP0 0001 R12 SP0
CA11MUF:DB00101I - STARTED JOB-T311JDPE NUMBER--1706 CXX=AD12CXX MUFNAME=CA11MF SVC=221
CA11MUF:DB00501E - OPEN ERROR - RETURN CODE 76 (010) CXX=AD12CXX (IXX00601) MUFNAME=CA11MF1 SVC=221
DB10045E - ABNORMAL TERMINATION DUE TO ERROR(S)
IEF450I T311JDPE LINK12 - ABEND=S000 U0004 REASON=00000000
TIME=07.48.09
AAC03 T311JDPE LINK12 U0004 307 00.11 00.41 00

Above error occurring in second step of job AXFFB01 which allows to fallback to previous release.

Environment

z/os 2.2, CA Datacom/AD 15.0 falling back to 12.0

Cause

PREVIOUS OPEN ERROR REQUIRES CLOSE   BEFORE NEW OPEN ATTEMPT       
                                           
After some of the open error conditions,   it is required that a close occur to ensure full cleanup of conditions.                

Resolution

Adding the highlited CLOSE statement (job AXFFB01)  below resolved the case:

//SYSIN DD * 

COMM OPTION=CLOSE,DBID=601 
LINK DBID=601 
ACCESS STATUS=WRITE,DBID=601 
/* 
//*