Device model names are not get updated unless the device model is Reconfigured or the user clicks on Reconfiguration tab under Component Details.
Is there any other method to ensure that model name and system name stay in sync?
DX NetOps Spectrum 20.2 or later
Spectrum does not reconfigure the device models on a nightly basis.
Spectrum will automatically reconfigure a device model IF the following are true:
ifNumber
IfTablelastChange
ifStackLastChange
If Spectrum detects the current value read is different from the previous value, Spectrum will reconfigure the model
Otherwise, the model has to be manually reconfigured by doing one of the following:
NOTE: You can use the CLI reconfiguration update action in a script to run this update action on a list of models. Then, schedule the script to run periodically. Please be aware that running the model reconfiguration to often on too many models can cause a performance issue with the SpectroSERVER.